Title

Assessment of the efficiency of new bismuth composite shields in radiation dose decline to breast during chest CT

English Abstract

Bismuth shield has been recently introduced for radiation protection of patient radiosensitive organs such as breast during chest CT with image diagnosis capability. The purpose of this study was to evaluate the dose reduction and image quality conserve using new bismuth-silicon composite shields during chest CT. Materials and methods Scans were performed on a PMMA phantom using a 6-slice MDCT system. Dose reduction was calculated by placing ion-chamber in the 12 o’clock position for breast dose measuring. Chest CT scans was performed with and without new bismuth composite shields 10% by 0.5 mm and 1 mm thicknesses. Image quality was assessed by CT numbers and noise evaluation. Results The results of using bismuth composite shields induced to dose reduction to 7% and 12% for 0.5 mm and 1 mm thicknesses, respectively. As a result of the using 0.5 mm and 1 mm bismuth composite shields, the mean CT numbers and noise increased by a factor of 0.01 and 0.02 and also from 0.08 to 0.13, respectively. Significant dose decline was measured and no relevant noise was found. Conclusion Results showed that new bismuth-silicon composite shields have good potential to breast dose reduction with smallest noise for diagnosis in chest CT.

Item Type:Article
زبان سند : انگلیسی
نویسنده اول :پریناز محنتی
نویسنده مسئول :رضا ملک زاده
نویسنده :محمد یوسفی سوته
نویسنده :سهیلا رفاهی
Additional Information:Indexed in: ESCI, Scopus, EMBASE, DOAJ
کلیدواژه ها (انگلیسی):Bismuth-silicon composite shield , Dose reduction ,Chest CT , Image quality
Subjects:WN Radiology . Diagnostic Imaging
Divisions:Faculty of Medicine > Department of Basic Sciences > Department of Medical Physics
ID Code:10583
Deposited By: MS Soheila Refahi
Deposited On:20 Sep 1397 13:59
Last Modified:20 Sep 1397 14:35

Repository Staff Only: item control page

Document Downloads

More statistics for this item...