حضرتی, صادق and هاراد, استوارت (1385) کالیبراسیون نمونه بردارهای پاسیو برای اندازه گیری کمی PCB و PBDE فاکتورهای تاثیر گذار در میزان نمونه برداری. Chemosphere ــ 67 (3). pp. 448-455. شاپا 0045-6535
This is the latest version of this item.
![]() |
Text
- Published Version
محدود به Repository staff only 264kB | |
|
Text
- Published Version
60kB |
Official URL: http://www.sciencedirect.com
Title
Calibration of polyurethane foam (PUF) disk passive air samplers for quantitative measurement of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs): Factors influencing sampling rates.
English Abstract
PUF disk passive air samplers are increasingly employed for monitoring of POPs in ambient air. In order to utilize them as quantitative sampling devices, a calibration experiment was conducted. Time integrated indoor air concentrations of PCBs and PBDEs were obtained from a low volume air sampler operated over a 50d period alongside the PUF disk samplers in the same office microenvironment. Passive sampling rates for the fully-sheltered sampler design employed in our research were determined for the 51 PCB and 7 PBDE congeners detected in all calibration samples. These values varied from .57 to 1.55m(3)d(-1) for individual PCBs and from 1.1 to 1.9m(3)d(-1) for PBDEs. These values are appreciably lower than those reported elsewhere for different PUF disk sampler designs (e.g. partially sheltered) employed under different conditions (e.g. in outdoor air), and derived using different calibration experiment configurations. This suggests that sampling rates derived for a specific sampler configuration deployed under specific environmental conditions, should not be extrapolated to different sampler configurations. Furthermore, our observation of variable congener-specific sampling rates (consistent with other studies), implies that more research is required in order to understand fully the factors that influence sampling rates. Analysis of wipe samples taken from the inside of the sampler housing, revealed evidence that the housing surface scavenges particle bound PBDEs.
Item Type: | Article |
---|---|
زبان سند : | انگلیسی |
نویسنده اول : | صادق حضرتی |
نویسنده مسئول : | استوارت هاراد |
Additional Information: | Cited By in Scopus :19 Impact Factor: 3.054 Abstracting and Indexing: 1- Medline,ISI 2-BIOSIS,Chemical Abstracts,EMBASE,Scopus 3- Analytical Abstracts,Aqualine Abstracts,Cambridge Scientific Abstracts,Current Contents/Agriculture, Biology & Environmental Sciences,Elsevier BIOBASE, Environmental Periodicals Bibliography,PASCAL/CNRS,Research Alert,SCISEARCH,Science Citation Index |
کلیدواژه ها (انگلیسی): | Indoor air ; POPs ; Passive sampling rates ; Passive sampler design |
Subjects: | WA Public Health > WA 400 Occupational Medicin, health and hygiene WA Public Health > WA 400 Occupational Medicin, health and hygiene |
Divisions: | Faculty of Health > Department of Environmental health |
ID Code: | 1265 |
Deposited By: | Dr Sadeg Hazrati |
Deposited On: | 20 Feb 1389 11:20 |
Last Modified: | 23 Nov 1391 10:21 |
Available Versions of this Item
-
کالیبراسیون نمونه بردارهای پاسیو برای اندازه گیری کمی PCB و PBDE فاکتورهای تاثیر گذار در میزان نمونه برداری. (deposited 28 Nov 1388 06:12)
- کالیبراسیون نمونه بردارهای پاسیو برای اندازه گیری کمی PCB و PBDE فاکتورهای تاثیر گذار در میزان نمونه برداری. (deposited 20 Feb 1389 11:20) [Currently Displayed]