عنوان انگليسی

On the nature of indoor airborne bioaerosols at a hospital in Iran

خلاصه انگلیسی

Introduction: Hospitals are sensitive places owing to the contagious nature of diseases transferred by patients to others such as health care workers and staff. Materials and methods: The aim of the present work is to evaluate the type and concentration of bacterial and fungal bio-aerosols in the indoor air of four operating rooms (ORs) and four wards in Khalkhal, Iran during 2019. A total of 192 bacterial and fungal samples were collected. Results: Mean total concentrations of airborne bacteria for ORs and wards were between 11±1.2 to 48±3.1 CFU/m3, respectively, while for airborne fungi values ranged from 95±5.6 to 51±1.2 CFU/m3, respectively. The predominant genera of airborne bacterial isolated (ORs vs. wards) were Staphylococcus epidermidis (72% vs. 58%), Group D Streptococcus (4% vs. 17%), Group A Streptococcus (13% vs. 3%), and Staphylococcus saprophyticus (6% vs. 4%). In addition, the main fungal species identified (ORs vs. wards) were Cladosporium sp. (37% vs. 38%), Penicillium sp. (28% vs. 22%), and Aspergillus Niger (21% vs. 12%). A statistically significant correlation was observed between the mean concentration of bio-aerosols and population density (p<0.05). Conclusion: Furthermore, a statistically significant difference was observed between the mean concentrations of bio-aerosols and the values recommended by WHO (p<0.05), linked presumably to inadequate disinfection, improper design and operation of standard central ventilation (SCV), and the high density of visitors and patients. Addressing such issues can help reduce airborne fungi and bacteria in hospital.

نوع سند :مقاله
زبان سند : انگلیسی
نویسنده اول :مریم دشتی
نویسنده :عباس نوروزیان باقانی
نویسنده :آرمین سروشیان
نویسنده :مهدی وثوقی
نویسنده :سیداحمد مختاری
نویسنده مسئول :هادی صادقی
ضریب تاثیر و نمایه مجلات:Indexed in: Scopus
کلیدواژه ها (انگلیسی):Hospital; Indoor air quality; Bacteria; Fungi; Iran
موضوعات :WA بهداشت عمومي > WA 30 بهداشت محيط
WA بهداشت عمومي > WA 30 بهداشت محيط
بخش های دانشگاهی :دانشکده بهداشت > گروه بهداشت محیط
کد شناسایی :15122
ارائه شده توسط : دکتر مهدی وثوقی نیری
ارائه شده در تاریخ :22 دی 1400 14:14
آخرین تغییر :22 دی 1400 14:14

فقط پرسنل کتابخانه صفحه کنترل اسناد

Document Downloads

More statistics for this item...