title

ارزیابی میزان تابش اپراتور در طول آنژیوگرافی کرونری از طریق ترانس رادیال

طریقت نیا, علی ، پورافکاری, لیلی ، فرج الهی, علیرضا ، محمدعلیان, امیرحسین ، قوجازاده, مرتضی ، Nader, Nader D (1396) ارزیابی میزان تابش اپراتور در طول آنژیوگرافی کرونری از طریق ترانس رادیال. Herz ــ 43 (6). ص.ص.535-542. شاپا 0340-9937

متن کامل

[img]
پیش نمایش
متنی - نسخه چاپ شده
863kB

آدرس اینترنتی رسمی : https://link.springer.com/article/10.1007/s00059-0...


عنوان انگليسی

Operator radiation exposure during transradial coronary angiography

خلاصه انگلیسی

Background. The right radial artery has gained popularity as the preferred access site for coronary angiography. To save time and limit the radiation exposure of operators and patients, newly designed catheters can be used to access both the right and left coronary arteries. The aim of this study was to compare operator radiation exposure between single catheter (SCA) and two-catheter approaches (TCA). Methods. In all, 256 patients undergoing diagnostic coronary angiography via the right radial artery in a high-volume medical center were randomized to either the SCA or TCA group. The dose of radiation exposure of the operators was measured by an electronic dosimeter attached to the breast pocket of the operator’s apron. The dose–area product and air kerma were used as indices of patient exposure to radiation. The duration of fluoroscopy “beam-on” time, acquisition time, and total duration of the procedure were measured and analyzed for the two groups. Results. Operator radiation exposure was 21.6 ± 11.4 μSv in the SCA group, which was significantly less than 28.0 ± 14.9 μSv in the TCA group. The duration of fluoroscopy was significantly shorter in the SCA group than in the TCA group (152 ± 83 vs. 203 ± 121 s;p < 0.001). Moreover, the total duration of the diagnostic procedure was also shorter in the SCA group compared with the TCA group (9.5 ± 3.2 vs. 11.4 ± 4.0min; p < 0.001). Conclusion. The use of SCA is advantageous over TCA in reducing the exposure of operators to radiation. The shorter duration of fluoroscopy beam-on time and total procedure time may contribute to the lower exposure of operators to radiation.

نوع سند :مقاله
زبان سند : انگلیسی
نویسنده اول :علی طریقت نیا
نویسنده :لیلی پورافکاری
نویسنده :علیرضا فرج الهی
نویسنده :امیرحسین محمدعلیان
نویسنده :مرتضی قوجازاده
نویسنده مسئول :Nader D Nader
ضریب تاثیر و نمایه مجلات:IF: 0.995 Indexed in: ISI, PubMed/Medline, Scopus, Embase
کلیدواژه ها (فارسی):آنژیوگرافی عروق کرونری، تابش اشعه، شریان رادیال، کاتتریزاسیون، فلوروسکوپی
کلیدواژه ها (انگلیسی):Coronary angiography, Radiation exposure, Radial artery, Catheterization, Fluoroscopy
موضوعات :WN پرتو شناسی
بخش های دانشگاهی :دانشكده پزشكي > گروه علوم پایه > بخش فیزیک پزشکی
کد شناسایی :17390
ارائه شده توسط : دکتر علی طریقت نیا
ارائه شده در تاریخ :30 مرداد 1402 09:35
آخرین تغییر :30 مرداد 1402 09:35

فقط پرسنل کتابخانه صفحه کنترل اسناد

Document Downloads

More statistics for this item...