title

حذف میکروارگانیسم ها بوسیله اشعه UVC از هوای بیمارستان ها

دشتی, مریم ، درگاهی, عبداله ، صادقی, هادی ، وثوقی, مهدی ، مختاری, سیداحمد (1401) حذف میکروارگانیسم ها بوسیله اشعه UVC از هوای بیمارستان ها. Avicenna Journal of Environmental Health Engineering ــ 9 (1). ص.ص.35-44. شاپا 2423-4583

متن کامل

[img]
پیش نمایش
متنی - نسخه چاپ شده
1MB

آدرس اینترنتی رسمی : https://ajehe.umsha.ac.ir/Article/ajehe-4250


عنوان انگليسی

Removal of Microorganisms by UVC Radiation From the Air of Hospital

خلاصه انگلیسی

Currently, UVC radiation is used in hospitals to eliminate microorganisms and reduce adverse health effects in operating rooms (ORs) and protective environment rooms (PERs). The purpose of this study was to investigate the effect of UVC irradiation on bioaerosols in ORs and PERs. This experimental study was performed in ORs and PERs in a hospital. Bioaerosols were evaluated according to the National Institute for Occupational Safety and Health (NIOSH) standard (No. 0800). The samples were collected from indoor air of rooms before irradiation and after UVC(254 nm) irradiation for 20 and 480 minutes. The sample size of the study was determined to be 432 (216 fungi and 216 bacteria). The difference between the mean concentration of bioaerosols in the UVC radiation at two intervals (20 and 480 minutes) was significant, which indicates a decrease in the concentration of bioaerosols by increasing the duration of UVC radiation. Some bacteria, such as group B Streptococcus, Lactobacillus, and Listeria, were entirely killed after 20 minutes of irradiation; however, complete removal of the bacteria such as Staphylococcus pneumoniae and Staphylococcus saprophyticus was observed after 480 minutes of UVC irradiation. Fungi, such as Alternaria, Stofelim, and Mucor had a 100% reduction after 20 minutes of UVC irradiation, and Rhizopus and Aspergillus fumigatus showed a 100% decrease after 480 minutes of UVC irradiation. Other isolated fungi such as Cladosporium, Penicillium, Aspergillus niger, Rhodotorula, and Alternaria showed a decrease of 75%-98.78%. The ultraviolet (UV) sensitivity of bacterial and fungal bioaerosols depends strongly on their type. The results from this study may offer an important understanding of the control of indoor bioaerosols using UVC irradiation and help abate the environmental impacts of airborne microbes.

نوع سند :مقاله
زبان سند : انگلیسی
نویسنده اول :مریم دشتی
نویسنده :عبداله درگاهی
نویسنده مسئول :هادی صادقی
نویسنده :مهدی وثوقی
نویسنده :سیداحمد مختاری
ضریب تاثیر و نمایه مجلات:Indexed in: Scopus
کلیدواژه ها (انگلیسی):UVC radiation, Bio-aerosol, Hospital, Operating room, Protective environment room
موضوعات :WA بهداشت عمومي > WA 30 بهداشت محيط
WA بهداشت عمومي > WA 30 بهداشت محيط
بخش های دانشگاهی :دانشکده بهداشت > گروه بهداشت محیط
کد شناسایی :17998
ارائه شده توسط : دکتر هادی صادقی
ارائه شده در تاریخ :16 بهمن 1402 08:56
آخرین تغییر :16 بهمن 1402 08:56

فقط پرسنل کتابخانه صفحه کنترل اسناد

Document Downloads

More statistics for this item...