title

بررسي كفايت دياليز بيماران همو دياليزي مركز دياليز شهر اردبيل 1381

مظفری, ناصر (1380) بررسي كفايت دياليز بيماران همو دياليزي مركز دياليز شهر اردبيل 1381. [ research project ]

[img] PDF - Published Version
محدود به Repository staff only

221kB

Official URL: http://lib.arums.ac.ir

Persian Abstract

مقدمه : زمينه وهدف: چندين دهه است که از همودياليز به عنوان طرح درمان جايگزين در مبتلايان به نارسايي پاياني كليه استفاده مي گردد، اما هنوز به اين سوال كه يك بيمار اورميك به چه مقدار همودياليز نيازمند است پاسخ داده نشده است روشهاي متعددي براي بررسي ميزان نياز و كفايت همودياليز وجود دارد يكي از اين روشها، بررسي محاسبه KT/V بيماران همودياليز است و اين مطالعه هم با هدف «تعيين كفايت همودياليز بيماران همودياليزي مركز دياليز شهر اردبيل در سال 1381 » انجام گرديده است. روش تحقيق : در اين مطالعه توصيفي همه بيماراني كه در آن مركز دياليز مي شدند مورد بررسي قرارگرفته اند (70 نفر) از كليه بيماران قبل و بعد از انجام همودياليز نمونه خون تهيه و ميزان اوره و گلبولهاي خوني اندازه گيري شد براي بررسي كفايت دياليز از روشKT/V استفاده گرديد سپس اطلاعات جمع آوري شده با استفاده از نرم افزار آماري SPSS تجزيه وتحليل گرديد. و در تجزيه و تحليل اطلاعات از آمار توصيفي (ميانگين، انحراف معيار) و استنباطي (كاي دو) استفاده گرديد. نتايج : يافته ها نشان داد KT/V 90 درصد بيماران همودياليزي زير 2/1 بود. 3/54 درصد بيماران سه بار در هفته دياليز مي شدند. ميانگين طول مدت دياليز نمونه ها 63/1 4/2 سال بود و ميانگين هموگلوبين آنان 69/1 27/8 گرم در دسي ليتر بود همچنين يا فته ها نشان داد كه بين كفايت دياليز و نوع دستگاه رابطه آماري معني داري وجود نداشت. نتيجه گيري : در مجموع نتايج نشان داد با معيارKT/V درصد بسيار زيادي(90%) از بيماران اين مركز دياليز ناكافي دارند اميد است نتايج حاصل از اين تحقيق در جهت بهتر كردن وضعيت همودياليز بيماران آن مركز مورد استفاده قرارگيرد .

Title

Dialysis adequacy of haemodialytic patients in Ardabil Diaiysis Cnter (2002)

English Abstract

Background and objectives: In recent years haemodialysis has been several decades that used as a replacement therapy in end- stage renal failure patients. By now it isn't clear that how much a uremic patient need haemodialysis? ‏There are multiple methods for assessment of the needs and adequacy of dialysis. One of these methods was estimate of KT/V of haemodiolysis patients. The aim of this study was to determine dialysis adequacy of haemodialytic Patients in Ardabil dialysis center in the year 2002. Methods: In this descriptive study, all of the hemodialytic patients (70 cases) were selected in total sampling. Urea and blood cells were determined and KT/V methods were used for adequacy of dialysis. Data collectied were analyzed for descriptive (mean- standard deviation) and analytical (X2) statistical methods with SPSS software. Results: The results showed KT/V in 90% of cases was smaller than 1.2 and 54.3% of patients dialyzed three times in a week; mean of dialysis duration was 2.4 ±63 years. mean of hemoglobin was 8.27± 1/69gr/dc ,also, the results showed that there was no significant relationship between dialysis adequacy and instruments type on the basis of results of this study ,90% of haemodialytic patties in Ardabil Center ,in terms of KT/V criteria, did not have adequacy of dialysis and it was suggested that these results were used to improve and increase in the adequacy of dialysis.

Item Type: research project
زبان سند : فارسی
project status : اتمام یافته
مجری اصلی :ناصر مظفری
تاریخ اتمام :19 June 1380
Uncontrolled Keywords:نارسايی مزمن كليه ، همودياليز ، كفايت ، اردبيل
کلیدواژه ها (انگلیسی):chronic renal failer, haemodialysis,adequacy,dialysis center
Subjects:WJ Urogenital System
WY Nursing
Divisions:Faculty of Nursing & Midwifery > Department of Nursing
Vice Chancellor for Research and Technology > Deputy for Research and Technology management and Medical Information > completed research projects
ID Code:400
Deposited By: MS Soghra Golmaghani
Deposited On:30 Jul 1388 10:00
Last Modified:14 Jun 1391 13:52

Repository Staff Only: item control page

Document Downloads

More statistics for this item...