title

مقایسه طول كارکردتعیین شده توسط آپكس ياب DELTA و دستگاه راديوگرافي به روش In Vitro

بلوریان, مهرداد and امانی, فیروز and شریفی, فریبرز (1392) مقایسه طول كارکردتعیین شده توسط آپكس ياب DELTA و دستگاه راديوگرافي به روش In Vitro. MD (پایان نامه) دانشگاه علوم پزشکی اردبیل.






[img]
Preview
Text - final reserch project report
78kB
[img] Text - final reserch project report
محدود به Repository staff only

1MB
[img]
Preview
Text - final reserch project report
1MB
[img] Text - final reserch project report
محدود به Repository staff only

913kB
[img] Other (SPSS) - فایل ضمیمه
محدود به Repository staff only

2kB

Official URL: http://lib.arums.ac.ir

Persian Abstract

سابقه و هدف: يكي از مهم ترين مراحل درمان اندودنتيك پاكسازي و شكل دهي مناسب كانال هاي ريشه بر اساس طول کارکرد دقیق مي باشد. تا امروز روش هاي متعددي براي تعيين طول كاركرد مطرح شده است كه يكي از روش هاي رايج و متداول براي تعيين طول كاركرد كانال استفاده از راديوگرافي است. با اين حال بدلیل محدوديت هائي که در رادیو گرافی وجود دارد تلاش برای پبیشبرد تکنولوژی در زمینه تعيين طول كاركرد درجهات مختلفی انجام شده است و بر این اساس آپکس یابهای الکترونیکی به بازار ارائه شده اند.هدف ما از این مطالعه تعیین طول كاركرد اندازه گیری شده توسط آپكس ياب DELTAو مقایسه آن با دستگاه راديوگرافي به روش In Vitroمیباشد. مواد و روشها: در این مطالعه تعداد 67 دندان دائمی تک کانال کشیده شده با آپکس بالغ به سه روش مورد بررسی قرارگرفت. ابتدا طول واقعی هر کانال ریشه توسط چشم تعیین گردید. سپس تمامی کانالها یک بار بوسیله رادیوگرافی به روش موازی و یکبار بوسیله دستگاه آپكس ياب DELTA تعیین طول شدند. یافته های بدست آمده جمع آوری و بوسیله تست آزمون T زوجی مورد تجزیه و تحلیل قرار گرفتند. یافته ها: از 67 دندان مورد مطالعه در 44 کانال طول تعيين شده توسط دستگاه راديوگرافي و آپكس ياب DELTA با هم همخوانی داشتند. نتیجه گیری: در مطالعه فوق نشان داده شد که دستگاه آپكس ياب DELTA دقتی معادل 6/77% با خطای 5/ ± میلی متر و دستگاه رادیوگرافی دقتی معادل 97% با خطای 5/ ± میلی متر را داشتند.

Title

Comparison of Determinated Working Length by DELTA Apex Locator and Radiography : An In Vitro Study

English Abstract

Background: One of the most important stages of endodontic treatment is cleaning & shaping of root canals within exact working length.up to now many methods have been introduced to determine working length and one of the common methods for determining the working length is radiograghy. Although there are many limitations in radiograghic method and much effect has been making for the progress of technology in many ways of this field and following these attempts, electronic apex locators were introduced. Our purpose in this in vitro study is to determine the working length by DELTA apexlocator and to compare with radiography. Material and Methods: Sixty seven extracted single-rooted permanent teeth were used for this study. The actual working length of each root canal was determined visually, then working length of the all canals were determined by Radiographic method and DELTA apex locator. Data were analyzed by paired T test. Results: In the present study in 44 canals of 67 canals the working length determination was similar between Radiographic method and DELTA apex locator. Conclusion: Results presented an accuracy of %77/6 for DELTA apex locator and %97 for radiography When considering the margin of ±0/5mm.

Item Type:Thesis ( MD)
زبان سند : فارسی
استاد راهنما :مهرداد بلوریان
استاد مشاور :فیروز امانی
نگارنده :فریبرز شریفی
Additional Information:شماره پایان نامه : 01
Uncontrolled Keywords:تنگه آپیکال ، طول کارکرد ، آپكس ياب ، طول کارکرد رادیو گرافی
کلیدواژه ها (انگلیسی):Apical Constriction , Working length , Apex locator , Radiographic Working length
Subjects:WN Radiology . Diagnostic Imaging
WU Dentistry. Oral surgery
Divisions:?? 16 ??
Faculty of Medicine > research unit > sumitted thesis
Faculty of Medicine > Department of Basic Sciences > Department of Vital Statistics
ID Code:4383
Deposited By: MS Soghra Golmaghani
Deposited On:25 Apr 1392 11:19
Last Modified:26 Mar 1399 10:35

Repository Staff Only: item control page

Document Downloads

More statistics for this item...