دبیرمقدم, ابوالفضل ، رازجو, فرهاد (1391) مقایسه روش دستی برای تشخیص آلودگی های گوناگون باکتریایی در فرآورده ها. در: The 13th Iranian & The Second International Congress of Microbiology, July 14 – 16, 2012, Ardabil - Iran.
متن کامل
|
متنی
- نسخه چاپ شده
258kB |
آدرس اینترنتی رسمی : http://congress.arums.ac.ir/index.php/IICM/5/sched...
عنوان انگليسی
Comparison of the Bact/Alert Blood Culture System and Manual Culture Methods for Detection of Aerobic and Facultative Anaerobic Bacterial Contamination in Platelet Concentrates
خلاصه انگلیسی
Background & Objectives: Bacterial contamination evaluation of blood products is regarded as important point of blood safety. Since platelets should be stored at 20 to 24C° that makes them an excellent growth medium for bacteria, it is mentioned as a major problem in transfusion medicine. For reducing this risk, FDA has approved the Bact/Alert (Biomerieux- France) for screening the platelet units. This study attempt to compare the Bact /Alert system and manual culture methods regarding length of time in hours to detection. Methods: In this interventional and diagnostic study 15 platelet unit were selected randomly among 1332 unit and inoculated by 10 CFU/mlof various bacteria which contaminate platelet units routinely including streptococci, serratia marcescens, enterobacter cloaceae, corynebacterium diphteroied , staphylococci aureus and staphylococci epidermidis . Then these units with other platelet units were tested by Bact/Alert system and manual Methods as unknown sample. Results: Regarding the shortage of platelet unit expiration time if length of time in hours to detection is used as a basis for comparison , the Bact/Alert system is significantly superior to manual Methods , insofar as it detects positives significantly faster .The medium length of time in hours for detecting the aerobic bacterias by Bact/Alert system is 31 hours ( SD: ±8) following inoculation of samples to medium bottles in comparison 61 hours( SD: ±11) by manual Methods .This time is by Bact/Alert system is nearly 2 time faster than manual Methods. Conclusion: Bact/Alert culture system in compare with manual Methods is more rapid and accurate for detection of bacterial contamination and so platelet safety will improve by using this system .
نوع سند : | موضوع کنفرانس یا کارگاه (پوستر ) |
---|---|
زبان سند : | انگلیسی |
نویسنده مسئول : | ابوالفضل دبیرمقدم |
کلیدواژه ها (انگلیسی): | Platelet Concentrate; Bacterial Contamination; Bact/Alert; Manual Culture |
موضوعات : | QW میکروب شناسی و ایمنی شناسی WH سیستم های خونی و لنغاوی |
بخش های دانشگاهی : | معاونت تحقیقات و فناوری > مديريت تحقیقات و فناوری و اطلاع رساني > مدیریت همایش ها و کنگره های دانشگاه |