title

بررسی ارتباط بین یافته های داپلر کاروتید و neuroimaging و functional state در روز اول ضایعه ی حاد عروق مغز (هموراژیک و ایسکمیک) در بیماران مراجعه کننده به بیمارستان علوی در سال 94

فتاح زاده اردلانی, قاسم and قریشی, اسماعیل and قلیزاده, امیر (1395) بررسی ارتباط بین یافته های داپلر کاروتید و neuroimaging و functional state در روز اول ضایعه ی حاد عروق مغز (هموراژیک و ایسکمیک) در بیماران مراجعه کننده به بیمارستان علوی در سال 94. MD (پایان نامه) دانشگاه علوم پزشکی اردبیل.






[img]
Preview
Text - final reserch project report
386kB
[img]
Preview
Text - final reserch project report
23kB
[img] Text - final reserch project report
محدود به Repository staff only

2MB
[img] Text - final reserch project report
محدود به Repository staff only

912kB
[img] Other (spss) - فایل ضمیمه
محدود به Repository staff only

2kB

Official URL: http://lib.arums.ac.ir

Persian Abstract

مقدمه: بیماری عروق مغز(CVA) سومین علت مرگ در ایالات متحده است که مسئول بیش از163000 مرگ در سال 2012 بوده است. سونوگرافی شریان های کاروتید روش انتخابی برای تشخیص و زیر نظر داشتن اشخاص با بیماری atheromatous است. با توجه به ارزش تشخیصی و بالینی سونوگرافی داپلر عروق extracranial مغز، شناسایی یافته های به دست آمده در بیماران مشکوک برای CVA و TIA وتعیین شیوع آن ها از اهمیت به خصوصی برخوردار است. در مطالعه حاضر به رابطه سونولوژی(سونوگرافی داپلر و TCD) و سطح عملکردی بیماران مبتلا به CVA ایسکمیک و هموراژیک پرداخته شده است. مواد و روش ها: مطالعه حاضر از نوع بررسی مقطعی می باشد و بر روی 100 بیمار مبتلا به سکته مغزی مراجعه کننده به بیمارستان علوی اردبیل می پردازد. بیماران در این مطالعه تحت سی تی اسکن و سونوگرافی داپلر و TCD قرار گرفتند. داده های حاصل با استفاده از نرم افزار SPSS-20 مورد تجزیه و تحلیل قرار گرفتند. نتایج: میانگین سنی بیماران 11.1±66.3 است و 53 درصد از بیماران را زنان تشکیل می دهند. فشار خون بالا، بیماری قلبی زمینه ای، سیگار و دیابت ریسک فاکتورهای اصلی در این مطالعه هستند. 58 درصد از بیماران در سطح عملکردی در ناتوانی متوسط و متوسط تا شدید قرار داشتند. وجود پلاک آترومی، افزایش ضخامت انتیما - مدیا و تغییر سرعت در شریان کاروتید خارجی به ترتیب بیشترین فراوانی را در بررسی سونوگرافی داپلر بیماران داشتند. رابطه معناداری بین نتایج حاصل از TCD و سطح عملکردی بیماران وجود نداشت. نتیجه گیری: با توجه به عدم معناداری رابطه نتایج TCD و سطح عملکردی بیماران در این مطالعه برای بررسی دقیق تر این موضوع نیاز به بررسی TCD بیماران در چند روز متفاوت و پس از شروع درمان بیمار وجود دارد.

Title

The correlation between color duppler and neuroimaging findings and patients functional states at first day of acute cerebrovascular accidents (haemorrhagic and ischemic) in patients admitted in Ardabil's Alavy hospital in 1394

English Abstract

Introduction: Cerebrovascular accident (CVA) is the third leading cause of death in the United States of America which was responsible for the death of 163000 people in 2012. Sonography of carotid arteries is the preferred method of diagnosing and monitoring people with atheromatous. Considering the diagnostic and clinical value of sonography of extrcranial vessels of the brain, identifying findings obtained from patients suspected of having CVA and TIA and their prevalence is of great importance. The present study seeks to investigate the correlations between Sonology (Doppler Sonography and TCD) and the functional state of ischemic and hemorrhagic CVA patients. Materials and method: The current study is a cross-sectional investigation of 100 stroke patientsadmitted to Alavi hospital of Ardabil. Patients in the present study underwent CT scan, Doppler sonography, and TCD. The obtained data were analyzed using SPSS. Results: The mean age of the patients were 66.3±11 and women constituted 53 per cent of the patients. High blood pressure, underlying heart disease, smoking, and diabetes were the major risk factors in the present study. Fifty eight per cent of the patients in the functional state were at moderate or moderate to severe disability. Atheromatous plaques, intima-media thickening, and the change of speed in the external carotid artery were most frequent in Doppler sonography investigations. There was no significant correlation between the obtained results from TCD and the functional state of the patients. conclusion: Considering the non-significant correlation between TCD results and the functional state of the patients in this study, a more detailed scrutiny of this subject requires the TCD investigation of the patients on several different days and after the initiation of the treatment of the patients.

Item Type:Thesis ( MD)
زبان سند : فارسی
استاد راهنما :قاسم فتاح زاده اردلانی
استاد مشاور :اسماعیل قریشی
دانشجو :امیر قلیزاده
Additional Information:شماره پایان نامه : 576 ، پایان نامه دکتری حرفه ای پزشکی
Uncontrolled Keywords:سونوگرافی داپلر کاروتید، سطح عملکردی بیماران
کلیدواژه ها (انگلیسی):CVA, TCS, carotid Doppler sonography, functional state of patients
Subjects:WL Nervous system
Divisions:Faculty of Medicine > research unit > sumitted thesis
Faculty of Medicine > Department of Dermatology , Psychiatry , Neurology
ID Code:7861
Deposited By: Mr farhad khodaei
Deposited On:04 Aug 1395 06:39
Last Modified:14 Feb 1399 18:55

Repository Staff Only: item control page

Document Downloads

More statistics for this item...