title

مقایسه خروج اپیکالی دبری با استفاده از Single-File ، Full Sequence Rotary و Reciprocating Systems

احسانی, مریم and فرهنگ, رباب and هرندی, آزاده and توانافر, سعید and رئوف, مریم and گله دار, سعیده (1395) مقایسه خروج اپیکالی دبری با استفاده از Single-File ، Full Sequence Rotary و Reciprocating Systems. Journal of Dentistry of Tehran University of Medical Sciences ــ 13 (6). pp. 394-399. شاپا 2008-2185

[img]
Preview
Text
260kB

Official URL: http://jdt.tums.ac.ir/index.php/jdt


Title

Comparison of Apical Extrusion of Debris by Using Single-File, Full-Sequence Rotary and Reciprocating Systems

English Abstract

Objectives: During root canal preparation, apical extrusion of debris can cause inflammation, flare-ups, and delayed healing. Therefore, instrumentation techniques that cause the least extrusion of debris are desirable. This study aimed to compare apical extrusion of debris by five single-file, full-sequence rotary and reciprocating systems. Materials and Methods: One hundred twenty human mandibular premolars with similar root lengths, apical diameters, and canal curvatures were selected and randomly assigned to six groups (n=20): Reciproc R25 (25, 0.08), WaveOne Primary (25, 0.08), OneShape (25, 0.06), F360 (25, 0.04), Neoniti A1 (25, 0.08), and ProTaper Universal. Instrumentation of the root canals was performed in accordance with the manufacturers’ instructions. Each tooth's debris was collected in a pre-weighed vial. After drying the debris in an incubator, the mass was measured three times consecutively; the mean was then calculated. The preparation time by each system was also measured. For data analysis, one-way ANOVA and Games-Howell post hoc test were used. Results: The mean masses (±standard deviation) of the apical debris were as follows: 2.071±1.38mg (ProTaper Universal), 1.702±1.306mg (Neoniti A1), 1.295±0.839mg (OneShape), 1.109±0.676mg (WaveOne), 0.976±0.478mg (Reciproc) and 0.797±0.531mg (F360). Compared to ProTaper Universal, F360 generated significantly less debris (P=0.02). The ProTaper system required the longest preparation time (mean=88.6 seconds); the Reciproc (P=0.008), OneShape (P=0.006), and F360 (P=0.001) required significantly less time (P<0.05). Conclusions: All instruments caused extrusion of debris through the apex. The F360 produced significantly less debris than did the ProTaper Universal.

Item Type:Article
زبان سند : انگلیسی
نویسنده اول :مریم احسانی
نویسنده مسئول :رباب فرهنگ
نویسنده :سعیده گله دار
Additional Information:Indexed in: PMC , Chemical Abstract, SID, IMEMR, Index Copernicus, Iran Medex.
کلیدواژه ها (انگلیسی):Dentistry; Endodontics; Root Canal Preparation; Instrumentation
Subjects:WU Dentistry. Oral surgery > Dentistry Oral Surgery Education WU.18
Divisions:Department of Dentistry > Department of Oral Surgery, and Maxillofacial
ID Code:8757
Deposited By: Dr Robab Farhang
Deposited On:08 Mar 1396 04:37
Last Modified:27 Jun 1397 09:54

Repository Staff Only: item control page

Document Downloads

More statistics for this item...